Item # |
Voltage |
No. of Conductors |
Diameter |
Gauge |
Conductor Material |
Shield |
Insulation Material |
Quantity |
---|---|---|---|---|---|---|---|---|
2075SJ | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.420 in | Gauge N/A 12 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2215SJ | Voltage N/A 10 KVAC30 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.410 in | Gauge N/A 16 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2012SJ | Voltage N/A 15 KVAC40 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.420 in | Gauge N/A 18 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2032SJ | Voltage N/A 15 KVAC50 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.470 in | Gauge N/A 16 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2024SJ | Voltage N/A 20 KVAC60 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.525 in | Gauge N/A 12 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2240 | Voltage N/A 20 KVAC60 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.670 in | Gauge N/A 12 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A EPR | |
2062SJ | Voltage N/A 30 KVAC100 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.810 in | Gauge N/A 8 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2242 | Voltage N/A 30 KVAC100 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.850 in | Gauge N/A 10 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A EPR | |
2186 | Voltage N/A 15 KVAC40 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.620 in | Gauge N/A 16 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2032TJ | Voltage N/A 15 KVAC50 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.550 in | Gauge N/A 16 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2024TJ | Voltage N/A 20 KVAC60 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.600 in | Gauge N/A 12 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2241 | Voltage N/A 25 KVAC75 KVDC | No. of Conductors N/A 1 | Diameter N/A 1.000 in | Gauge N/A 14 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A EPR | |
2217 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 4 | Diameter N/A 0.590 in | Gauge N/A | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2111 | Voltage N/A 15 KVAC50 KVDC | No. of Conductors N/A 4 | Diameter N/A 0.950 in | Gauge N/A 16 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2228 | Voltage N/A 15 KVAC50 KVDC | No. of Conductors N/A 3 | Diameter N/A 0.830 in | Gauge N/A 16 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2232A | Voltage N/A 3 KVAC10 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.300 in | Gauge N/A 6 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Polyethylene | |
2208 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.381 in | Gauge N/A 4 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2132 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.300 in | Gauge N/A 6 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2139 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.256 in | Gauge N/A 8 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2202 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.230 in | Gauge N/A 10 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2185 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.126 in | Gauge N/A 20 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2215 | Voltage N/A 10 KVAC30 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.275 in | Gauge N/A 16 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2178 | Voltage N/A 10 KVAC30 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.186 in | Gauge N/A 20 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2149 | Voltage N/A 20 KVAC60 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.230 in | Gauge N/A 18 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Polyethylene | |
2062S | Voltage N/A 30 KVAC100 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.700 in | Gauge N/A 8 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber |