Wire & Cable
All Categories
The high voltage wire and cable options listed below can be customized (e.g. shielded and/or jacketed with the materials of your choice) to your specifications. Contact our engineering department for more information.
Item # |
Voltage |
No. of Conductors |
Diameter |
Gauge |
Conductor Material |
Shield |
Insulation Material |
Quantity |
---|---|---|---|---|---|---|---|---|
2244 | Voltage N/A 20 KVAC60 KVDC | No. of Conductors N/A 3 | Diameter N/A 0.650 in | Gauge N/A 18 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Polyethylene | |
2245 | Voltage N/A 10 KVAC25 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.620 in | Gauge N/A 11 AWG | Conductor Material N/A Bare Copper | Shield N/A Bare Copper | Insulation Material N/A Polyethylene | |
2249 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 9 | Diameter N/A 0.538 in | Gauge N/A | Conductor Material N/A Silicone-insulated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2250 | Voltage N/A 10 KVAC25 KVDC | No. of Conductors N/A 1 | Diameter N/A 1.140 in | Gauge N/A 6 AWG | Conductor Material N/A Bare Copper | Shield N/A Bare Copper | Insulation Material N/A Polyethylene | |
2255 | Voltage N/A 10 KVAC25 KVDC | No. of Conductors N/A 1 | Diameter N/A 1.550 in | Gauge N/A 0000 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A EPR | Insulation Material N/A EPR | |
2265 | Voltage N/A 60 KVAC150 KVDC | No. of Conductors N/A 1 | Diameter N/A 1.010 in | Gauge N/A 2 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Polyethylene | |
2266 | Voltage N/A 50 KVAC160 KVDC | No. of Conductors N/A 4 | Diameter N/A 1.040 in26 mm | Gauge N/A | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A EPR | |
2289 | Voltage N/A 25 KVAC75 KVDC | No. of Conductors N/A 3 | Diameter N/A 0.650 in16 mm | Gauge N/A | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A EPR | |
2296 | Voltage N/A 125 KVAC400 KVDC | No. of Conductors N/A 1 | Diameter N/A 1.500 in | Gauge N/A 4 AWG | Conductor Material N/A Bare Copper | Shield N/A Copper Tape | Insulation Material N/A Laminate | |
6905 | Voltage N/A 3 KVAC10 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.105 in | Gauge N/A 22 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Unshielded | Insulation Material N/A Teflon |